mirror of
https://github.com/deepseek-ai/3FS.git
synced 2026-11-05 00:47:47 +00:00
[GH-ISSUE #245] 2 * 100Gbps RDMA network cards, single client write throughput can only reach 6GiB/s ??? #151
Labels
No labels
pull-request
No milestone
No project
No assignees
1 participant
Notifications
Due date
No due date set.
Dependencies
No dependencies set.
Reference
deepseek-ai/3FS#151
Loading…
Add table
Add a link
Reference in a new issue
No description provided.
Delete branch "%!s()"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
Originally created by @zk-kiger on GitHub (Apr 17, 2025).
Original GitHub issue: https://github.com/deepseek-ai/3FS/issues/245
Deploy 6 storage nodes(24 * nvmeSSD per node), all with 2 * 100Gbps network cards, network card model
0000:17:00.0 Ethernet controller: Mellanox Technologies MT2892 Family [ConnectX-6 Dx]
0000:17:00.1 Ethernet controller: Mellanox Technologies MT2892 Family [ConnectX-6 Dx]
Client fio can only run at 6GiB/s, the fio command is as follows:
Does this capability meet 3FS expectations? Are there other optimization parameters that are not enabled?
@feeyman commented on GitHub (Apr 23, 2025):
@zk-kiger Hello, may I ask if your issue has been resolved? By the way, what is the performance test for sequential reading?
@zk-kiger commented on GitHub (Apr 23, 2025):
not yet, single client sequential read can reach 18GiB/s
@RangerCD commented on GitHub (Apr 25, 2025):
I built a 3FS cluster at about 1/6 of your scale(23 SSDs total), and the performance I achieved is also roughly 1/6 of yours(~900MiB/s). I believe my observed performance aligns with expectations and 3FS's design principles, since I'm using QLC SSDs with poor direct write speed. Could you share the SSD model you used in your setup?
@zk-kiger commented on GitHub (Apr 25, 2025):
Intel SSDPF2KX076T1 Hard Drive 7.68TB SSD PCIe 4.0 x4 NVMe U.2 15mm TLC
@RangerCD commented on GitHub (Apr 29, 2025):
With this SSD, your cluster should achieve approximately 60GiB/s in write performance.
@Funny-Boy-Max commented on GitHub (Apr 29, 2025):
佬,请问你的测试命令是什么,我这边4个存储节点,1个元数据节点,存储节点内2个SSD,我这边测试下来是8467MB/s,但是我无法监测RDMA网络流量,这是为什么,具体如何能够监测到读写测试中,RDMA的使用带框情况
@bugwz commented on GitHub (May 9, 2025):
@Funny-Boy-Max iftop的流量不统计 ib 流量,为此你可以直接统计对应网卡设备的数据信息来监控对应 ib 的网络流量,给你提供一个脚本。
@Funny-Boy-Max commented on GitHub (May 12, 2025):
兄弟靠谱